MF420-P
The measuring systems of the product family MF420-P, with a catalytic sensor (pellistor), determine the concentration of explosive gases and vapors in air mixtures. The concentration is given out via a 4 - 20 mA interface for further processing. The sensor is characterized by its high measurement accuracy and by its long life cycle. The measuring range is from 0 – 100% LEL.
In combination with our limit monitors (GWZ) gas measurement systems for detection of explosive gases and vapors in ambient air, like eg. storage facilities, can be set up.
The measuring ranges depend on the measured gas or vapor. For a table of ranges please refer to the product assortment. Other gases, vapors, and concentrations are also possible on request. The device complies with the generic standard EN 50270:2015 Type 1 and Tyee 2 and Directive 2014/30/EC. The device is delivered already calibrated. The maintenance cycle must / should correspond to the given safety requirements. We recommend at least a semi-annual inspection of the equipment by qualified personnel. You can also use our service. For more details, please refer to the technical data or ask our contact person.
Other gases & vapors on request.
Measuring Ranges
Certifications
Maintenance and Service
Product Name Product Features Product Code
MF420-P
Hydrogen, LEL 4 vol%
Measuring Range 0 - 100% LELG2C0-P19JU-A100-O17
MF420-P
Methane, LEL 4,4 vol%
Measuring Range 0 - 100% LELG2C0-P19JU-A100-O11
MF420-P
Propane, LEL 1,7 vol%
Measuring Range 0 - 100% LELG2C0-P19JU-A100-O12
MF420-P
n-Butane, LEL 1,4 vol%
Measuring Range 0 - 100% LELG2C0-P19JU-A100-O03
MF420-P
LPG (50%-50%), LEL 1,5 vol%
Measuring Range 0 - 100% LELG2C0-P19JU-A100-O50
MF420-P
Ethanol, LEL 3,1 vol%
Measuring Range 0 - 100% LELG2C0-P19JU-A100-O05
MF420-P
Methanol, LEL 6 vol%
Measuring Range 0 - 100% LELG2C0-P19JU-A100-O20
MF420-P
Isopropyl, LEL 2 vol%
Measuring Range 0 - 100% LELG2C0-P19JU-A100-O08
MF420-P
Xylene, LEL 1 vol%
Measuring Range 0 - 100% LELG2C0-P19JU-A100-O18
MF420-P
n-Heptane, LEL 0,8 vol%
Measuring Range 0 - 100% LELG2C0-P19JU-A100-O07
MF420-P
n-Pentane, LEL 1,4 vol%
Measuring Range 0 - 100% LELG2C0-P19JU-A100-O51
Principle of Measurement
catalytic sensor (pellistor)
Power Supply
voltage
24 V DC (-15 % / +20 %)
current
< 140 mA
(power-on current < 1 A for approx. 5 ms)Connectors
3-pole screw terminal
0.5 mm² to 1.5 mm²
Ambient temperature
-10°C to +50°C
Air pressure
900 hPa to 1100 hPa
Permissible Humidity
15 to 95% relative humidity
non condensing
Output
4 - 20 mA
Housing
Alloy, red
Protection class
IP 54
Weight
approx. 500 g
Dimensions (L x W x H)
90 x 85 x 65 mm
Connecting Cable
3-wire cable
Pin Assignment:
Product Name Product Code
Replacement Sensor
G2C0-P19JU-A100-E02
Sensor mounting kit
G2C0-P19JU-A100-E41
Test gas cap
T0A0-A0001
Sinter metal, 10 pieces
U0A0-U0001