MF420-IR-CO2
The measuring system MF420-IR-CO2 determines by using a specific infrared sensor, the carbon dioxide concentration in the ambient at a temperature range from -10 to +50 ° C. It is compact, robust and low-maintenance in normal applications - we recommend at least an annual inspection. The housing is made of aluminum and suitable for wall mounting. The measured values are optionally provided via a 4..20 mA or 0...10 V interface. It is constantly self-monitoring and reports malfunctions of hardware and software.
New The product variant MF420-IR-T is optimized for use in cold stores. The temperature range is designed to -25 ° C. The application requires an on-site calibration.
The MF420-IR-CO2 is offered with the following standard measuring ranges: The CO2 concentration is output either via a 4..20 mA or a 0...10 V interface for further processing. The device complies with the generic standards EN 61000-6-2 and EN 61000-6-4 and thus the EMC Directive 2004/108/EC. The device thanks to its NDIR-Technology is low-maintenance - we recommend at least an annual inspection. For more details, please refer to the technical data or ask our contact person.
Please ask our contact person.
Measuring Ranges
Signal Outputs
Certifications
Maintenance and Service
Product Name Product Features Product Code
MF420-IR-CO2
Output: 4..20 mA
Measuring range: 0 - 3,000 ppmG2C0-I09NP-A100
MF420-IR-CO2
Output: 0..10 V
Measuring range: 0 - 3,000 ppmG2C0-I09NP-A200
MF420-IR-CO2
Output: 4..20 mA
Measuring range: 0 - 5,000 ppmG2C0-I09OP-A100
MF420-IR-CO2
Output: 0..10 V
Measuring range: 0 - 5,000 ppmG2C0-I09OP-A200
MF420-IR-CO2
Output: 4..20 mA
Measuring range: 0 - 6,000 ppmG2C0-I09PP-A100
MF420-IR-CO2
Output: 0..10 V
Measuring range: 0 - 6,000 ppmG2C0-I09PP-A200
MF420-IR-CO2
Output: 4..20 mA
Measuring range: 0 - 1 vol%G2C0-I09DV-A100
MF420-IR-CO2
Output: 0..10 V
Measuring range: 0 - 1 vol%G2C0-I09DV-A200
MF420-IR-CO2
Output: 4..20 mA
Measuring range: 0 - 2 vol%G2C0-I09EV-A100
MF420-IR-CO2
Output: 0..10 V
Measuring range: 0 - 2 vol%G2C0-I09EV-A200
MF420-IR-CO2
Output: 4..20 mA
Measuring range: 0 - 3 vol%G2C0-I09FV-A100
MF420-IR-T
Output: 4..20 mA
Measuring range: 0 - 3 vol%
Special version for -25°C (requires on-site calibration)G2C0-I09FV-A100-K31
MF420-IR-CO2
Output: 0..10 V
Measuring range: 0 - 3 vol%G2C0-I09FV-A200
MF420-IR-CO2
Output: 4..20 mA
Measuring range: 0 - 5 vol%G2C0-I09GV-A100
MF420-IR-CO2
Output: 0..10 V
Measuring range: 0 - 5 vol%G2C0-I09GV-A200
Principle of Measurement
NDIR (two-beam infrared photometer)
Power Supply
Voltage
24 V DC ± 5%
Current
approx. 100 mA
Ambient Temperature
-10°C to +50°C
Air Pressure
900 hPa to 1100 hPa
Permissible Humidity
15 to 95% relative humidity
non condensing
Output
4..20 mA
maximum ohmic resistance 450 Ω
or 0.1..10 V
minimum 1 KΩ
Housing
Alloy red
Protection class
IP 54
Weight
approx. 500 g
Dimensions (L x W x H)
90 x 85 x 65 mm
Pin Assignment: